GRANDMOTHERGLOBAL SETTINGS — MANUAL

The Grandmother has no screen. Behind the panel sits a layer of global settings that decide how the instrument behaves: MIDI, clock, voice allocation, CV ranges and more. This page explains what each setting does, with its values and factory default. Use it together with the editor, or with the synth’s own key commands.

Changing settings on the synth itself

“SysEx only” settings have no key command; you can only reach them with an editor. Requires firmware 1.1.0 or later.

MIDICHANNELS & PORTS

Unit ID

Values
0 … 15
Factory
0
On the synth
SysEx only
SysEx ID
0

Identifies this Grandmother in SysEx messages, so several Moog synths on one MIDI port can be addressed separately. This editor always talks to “all units” (7F), so you can normally leave this at 0.

MIDI channel in

Values
CH 1 … CH 16
Factory
CH 1
On the synth
Global setting 0.1
SysEx ID
10

The MIDI channel (1–16) Grandmother receives on. On the synth, setting 0.1 sets both the in and out channel at once.

MIDI channel out

Values
CH 1 … CH 16
Factory
CH 1
On the synth
Global setting 2.1
SysEx ID
11

The MIDI channel (1–16) Grandmother transmits on. On the synth, setting 2.1 changes only the out channel.

MIDI input ports

Values
NONE / DIN / USB / BOTH
Factory
BOTH
On the synth
SysEx only
SysEx ID
6

Which MIDI inputs Grandmother listens to: the 5-pin DIN socket, USB, both, or none. Handy to avoid doubled notes when the synth is connected both ways.

MIDI output ports

Values
NONE / DIN / USB / BOTH
Factory
BOTH
On the synth
SysEx only
SysEx ID
7

Which MIDI outputs Grandmother transmits on: the 5-pin DIN socket, USB, both, or none.

MIDI echo USB in

Values
OFF / →DIN / →USB / →BOTH
Factory
OFF
On the synth
SysEx only
SysEx ID
8

Re-transmits everything that arrives on the USB input to the DIN output, the USB output, or both. Careful with routing back to USB: this can create a MIDI loop.

MIDI echo DIN in

Values
OFF / →DIN / →USB / →BOTH
Factory
OFF
On the synth
SysEx only
SysEx ID
9

Re-transmits everything that arrives on the DIN input to the DIN output, the USB output, or both.

Transmit program change

Values
OFF / ON
Factory
OFF
On the synth
SysEx only
SysEx ID
4

When on, Grandmother sends a MIDI Program Change when you select a stored sequence. Not described in detail in Moog’s notes. Partly undocumented by Moog.

Receive program change

Values
OFF / ON
Factory
ON
On the synth
SysEx only
SysEx ID
5

When on, incoming MIDI Program Change messages select a stored sequence. Turn off to stop stray Program Changes from your DAW. Not described in detail in Moog’s notes. Partly undocumented by Moog.

Output 14-bit MIDI CCs

Values
OFF / ON
Factory
OFF
On the synth
SysEx only
SysEx ID
15

When on, controls that support it are sent as 14-bit CC pairs (CC 1–31 plus an extra LSB on CC number + 32) for smoother automation. Leave off if your gear only expects standard 7-bit CCs.

MIDI FILTERLOCAL CONTROL

MIDI out filter: keys

Values
OFF / ON
Factory
ON
On the synth
Global setting 2.4
SysEx ID
12

When on, playing the keyboard sends MIDI notes.

MIDI out filter: wheels

Values
OFF / ON
Factory
ON
On the synth
Global setting 2.3
SysEx ID
13

When on, moving the PITCH or MOD wheel sends MIDI messages.

MIDI out filter: panel

Values
OFF / ON
Factory
ON
On the synth
Global setting 2.2
SysEx ID
14

When on, turning panel controls sends MIDI CC messages, so you can record knob movements in your DAW. When off, no CCs are sent for panel changes.

Local control: keys

Values
OFF / ON
Factory
ON
On the synth
Global setting 0.10
SysEx ID
16

When off, the keyboard only plays via MIDI and no longer drives the internal sound engine. Moog notes that with Local off the KB OUT, GATE OUT and KB VEL OUT jacks are also disengaged, because they are hard-wired to the engine. On the synth, setting 0.10 switches local control as a whole; via SysEx keys, wheels and panel are separate.

Local control: wheels

Values
OFF / ON
Factory
ON
On the synth
Global setting 0.10
SysEx ID
17

When off, the PITCH and MOD wheels only send MIDI and no longer act on the internal engine.

Local control: panel

Values
OFF / ON
Factory
ON
On the synth
SysEx only
SysEx ID
18

When off, the panel controls that send MIDI no longer act on the internal engine directly, while their MIDI messages are still sent. Not described in Moog’s notes; this follows the usual meaning of local control. Partly undocumented by Moog.

KEYBOARD

Note priority

Values
LOW / HIGH / LAST
Factory
LAST
On the synth
Global setting 0.4
SysEx ID
3

Which note wins when you hold several keys on the monophonic keyboard: the LOWEST, the HIGHEST or the LAST note played.

Knob mode

Values
SNAP / PASS-THRU / RELATIVE
Factory
RELATIVE
On the synth
SysEx only
SysEx ID
2

Determines how a panel knob takes over after its parameter was changed remotely (for example by MIDI CC). SNAP jumps to the knob position as soon as you touch it, PASS-THRU waits until the knob passes the current value, RELATIVE moves the value from where it is. Not described in Moog’s notes; this follows the usual meaning of these modes. Partly undocumented by Moog.

Pitch bend range

Values
0 ST … 12 ST
Factory
2 ST
On the synth
Global setting 0.5
SysEx ID
34

The range of the PITCH wheel in semitones, 0 to 12 (one octave).

Keyboard octave transpose

Values
-2 OCT … +2 OCT
Factory
0 OCT
On the synth
SysEx only
SysEx ID
35

The current keyboard octave shift, −2 to +2 octaves, as set with the octave buttons on the left-hand controller.

Octave shift

Values
ON NEW NOTE / IMMEDIATELY
Factory
ON NEW NOTE
On the synth
Global setting 1.3
SysEx ID
36

How an octave change on the left-hand controller takes effect: ON NEW NOTE (default) only shifts the next note you play, IMMEDIATELY also shifts a note you are holding.

Tuning scale

Values
12-TET … SCALE 31
Factory
12-TET
On the synth
SysEx only
SysEx ID
1

Selects the active tuning table. Table 0 is always standard 12-tone equal temperament; other tables hold microtonal scales sent to the synth with a tuning tool.

GLIDE

Glide type

Values
LCR / LCT / EXP
Factory
LCR
On the synth
Global setting 1.1
SysEx ID
37

LCR (linear constant rate): bigger intervals take longer, the classic behaviour. LCT (linear constant time): every glide takes the same time regardless of interval. EXP (exponential): fast at first, slowing down towards the target note.

Gated glide

Values
OFF / ON
Factory
ON
On the synth
Global setting 1.2
SysEx ID
38

ON: the pitch only glides while a key is held; the glide pauses between notes and continues on the next key. OFF: the glide always completes in the time set by the GLIDE knob, whether or not a key is held.

Legato glide

Values
OFF / ON
Factory
OFF
On the synth
SysEx only
SysEx ID
39

When on, glide only happens when you play legato (a new key while the previous one is still held); detached notes go straight to their pitch.

OSCILLATORS

Osc 2 frequency knob range

Values
±0 ST … ±24 ST
Factory
±7 ST
On the synth
Global setting 1.6
SysEx ID
40

How far the Oscillator 2 FREQUENCY knob can detune, in semitones. The default of 7 is a perfect fifth. On the synth the range is 0–18; via SysEx up to 24.

Osc 2 hard sync

Values
OFF / ON
Factory
OFF
On the synth
Front-panel state
SysEx ID
41

Whether Oscillator 2 is hard-synced to Oscillator 1: the state of the orange SYNC button in the Oscillators section.

Pitch variance

Values
OFF … ±40.0 ct
Factory
OFF
On the synth
SysEx only
SysEx ID
43

Adds a small random detune to each note, up to the set maximum (±40 cents), for a lively, vintage-style instability. Only reachable via SysEx.

ENVELOPEMULTI TRIG

Multi trig

Values
OFF / ON
Factory
OFF
On the synth
Global setting 1.8
SysEx ID
42

OFF: the envelopes only retrigger after all keys are released and a new key is played. ON: they retrigger on every new key. Also MIDI CC 95; the editor follows changes live.

Multi trig reset speed

Values
4 ms … 50 ms
Factory
4 ms
On the synth
Global setting 1.9
SysEx ID
47

How long the envelope gate is held low when Multi Trig retriggers. Short (4 ms, FAST) suits plucky notes with zero sustain; longer (20 ms is SLOW on the synth) gives an audible re-attack even with a high sustain. Via SysEx anything from 4 to 50 ms.

ARP / SEQ

Sequence transpose mode

Values
FIRST NOTE / MIDDLE C
Factory
FIRST NOTE
On the synth
SysEx only
SysEx ID
19

How a running sequence is transposed from the keyboard. FIRST NOTE: the sequence is shifted so its first note matches the key you press. MIDDLE C: middle C is the reference, and the sequence plays as recorded on middle C.

Keyed timing reset

Values
OFF / ON
Factory
OFF
On the synth
SysEx only
SysEx ID
20

OFF: the arpeggiator stays locked to the clock, so a key pressed between steps waits for the next beat. ON: the note sounds immediately and the clock resets to the moment you pressed the key.

Arp FW/BW repeat end notes

Values
OFF / ON
Factory
ON
On the synth
SysEx only
SysEx ID
21

For the FW/BW direction. ON repeats the first and last note at each turn (C-E-G-G-E-C-C…), OFF does not (C-E-G-E-C-E…).

Swing

Values
0 % … 100 %
Factory
50 %
On the synth
SysEx only
SysEx ID
22

Moves the off-beat earlier or later for a swing feel. 50 % is straight timing, about 66 % is a triplet shuffle. Also available as MIDI CC 14.

Sequence keyboard control

Values
OFF / ON
Factory
ON
On the synth
SysEx only
SysEx ID
23

ON: pressing a key starts the sequence and sets its transposition. OFF: the sequencer runs on its own at its recorded pitch when you press PLAY, and you can play freely over it.

Delay sequence change

Values
OFF / ON
Factory
OFF
On the synth
SysEx only
SysEx ID
24

When you choose another sequence while one is running: OFF switches immediately, ON lets the current sequence finish first.

Sequence latch restart

Values
OFF / ON
Factory
—
On the synth
SysEx only
SysEx ID
25

Probably determines whether a latched (HOLD) sequence restarts from the first step when you play a new key. Moog lists it without a description or default. Partly undocumented by Moog.

Arp MIDI control mode

Values
ARP → MIDI OUT / MIDI IN → ARP
Factory
ARP → MIDI OUT
On the synth
SysEx only
SysEx ID
28

Only matters with local control off. ARP → MIDI OUT: the arpeggiator outputs MIDI notes and ignores incoming MIDI. MIDI IN → ARP: the arpeggiator outputs no MIDI notes, but is played by incoming MIDI notes.

Tap tempo division persistence

Values
OFF / ON
Factory
OFF
On the synth
Global setting 1.4
SysEx ID
44

Whether a clock division you chose while using tap tempo stays when tap tempo is switched off (ON), or is reset to eighth notes (OFF, default).

CLOCKSYNC

Clock input mode

Values
CLOCK / STEP ADVANCE
Factory
CLOCK
On the synth
Global setting 0.6
SysEx ID
26

What the rear CLOCK IN jack does. CLOCK: an external analog clock sets the tempo. STEP ADVANCE: every gate or trigger moves the arpeggiator or sequencer one step forward.

Clock output

Values
ALWAYS / WHEN PLAYING
Factory
WHEN PLAYING
On the synth
Global setting 1.7
SysEx ID
27

When the CLOCK OUT jack sends pulses: ALWAYS, or only WHEN PLAYING (arpeggiator or sequencer running). The pulse rate follows the tempo and the clock output PPQN.

Clock input PPQN

Values
1 PPQN … 48 PPQN
Factory
4 PPQN
On the synth
Global setting 0.7
SysEx ID
32

How many pulses per quarter note the external CLOCK IN signal delivers. Match your clock source: 4 PPQN = sixteenth notes (default), 24 PPQN = DIN sync style.

Clock output PPQN

Values
1 PPQN … 48 PPQN
Factory
4 PPQN
On the synth
Global setting 0.8
SysEx ID
33

How many pulses per quarter note Grandmother sends on CLOCK OUT. Match it to the gear you are clocking.

MIDI sync in

Values
CLOCK+START/STOP / CLOCK ONLY / IGNORE
Factory
CLOCK+START/STOP
On the synth
Global setting 0.2
SysEx ID
30

Whether the arpeggiator and sequencer follow incoming MIDI Clock and Start/Stop: both, clock only (ignore Start/Stop), or ignore everything.

MIDI sync out

Values
CLOCK+START/STOP / CLOCK ONLY / OFF
Factory
OFF
On the synth
Global setting 0.3
SysEx ID
29

Whether Grandmother sends MIDI Clock and Start/Stop: both, clock only, or nothing (the default).

Follow song position pointer

Values
OFF / ON
Factory
ON
On the synth
SysEx only
SysEx ID
31

When on, the sequencer follows MIDI Song Position Pointer, so it lines up correctly when your DAW starts playback in the middle of a song.

CV OUTPUTSVOLTAGE RANGE

KB OUT

Values
−5…+5 V / 0…10 V
Factory
−5…+5 V
On the synth
Global setting 0.9
SysEx ID
45

Voltage range of the KB OUT (pitch CV) jack: −5…+5 V or 0…+10 V. Match it to the gear you are driving.

KB VEL OUT

Values
−5…+5 V / 0…10 V
Factory
−5…+5 V
On the synth
Global setting 1.5
SysEx ID
46

Voltage range of the KB VEL OUT (velocity CV) jack: −5…+5 V or 0…+10 V.

Appendix: SysEx format

For the technically curious (values in hex, byte 0 = F0):

Set:      F0 04 16 23 [ID] [MSB] [LSB] 00 00 00 00 00 00 00 00 [Unit] F7
Request:  F0 04 16 3E [ID] 00 00 00 00 00 00 00 00 00 00 [Unit] F7
Reply:    same as Set, with byte 14 = 01

Values above 127 are split: MSB = value ÷ 128, LSB = value mod 128. Unit 7F addresses every unit.